69. Laying Batt insulation in studded walls should:

ansrbtn.jpg (1340 bytes) (a)  be butted up against any vent openings

ansrbtn.jpg (1340 bytes) (b)  have insulation at least 1 inch from any vent openings

ansrbtn.jpg (1340 bytes) (c)  be insulated at least 12 inches away from a vent openings

ansrbtn.jpg (1340 bytes) (d)  be laid over the vent openings

70. Batt insulation under a floor and over a crawl space should be
      placed:

ansrbtn.jpg (1340 bytes) (a)  under the joists with vapor barrier between the insulation and the floor

ansrbtn.jpg (1340 bytes) (b)  between the joists with vapor barrier between insulation and crawl space

ansrbtn.jpg (1340 bytes) (c)  over the joists with vapor barrier between the insulation and crawl space

ansrbtn.jpg (1340 bytes) (d)  between the joist with vapor barrier between the insulation and the floor

71. The use of cellulose insulation is a problem because:

ansrbtn.jpg (1340 bytes) (a)  without proper treatment, it is a fire hazard

ansrbtn.jpg (1340 bytes) (b)  it is difficult to install

ansrbtn.jpg (1340 bytes) (c)  it has a low R-value

ansrbtn.jpg (1340 bytes) (d)  it is very costly

72. What are used for lintels to support block over openings
      when dealing with concrete block foundation walls?

ansrbtn.jpg (1340 bytes) (a)  metal rods

ansrbtn.jpg (1340 bytes) (b)  metal lath

ansrbtn.jpg (1340 bytes) (c)  steel angles

ansrbtn.jpg (1340 bytes) (d)  all of the above

73. Why would you leave the vertical steel sticking out
      of the top after grouting a foundation wall?

ansrbtn.jpg (1340 bytes) (a)  to count the bars

ansrbtn.jpg (1340 bytes) (b)  to tie in the upper tier

ansrbtn.jpg (1340 bytes) (c)  rebar should not extend above the top

ansrbtn.jpg (1340 bytes) (d)  the inspector needs to see that the wall is reinforced

74. On masonry, the best kind of drill bit is?

ansrbtn.jpg (1340 bytes) (a)  high-carbon steel bit

ansrbtn.jpg (1340 bytes) (b)  auger-type bit

ansrbtn.jpg (1340 bytes) (c)   carbide-tipped bit

ansrbtn.jpg (1340 bytes) (d)  none of the above

75. You installed a concrete block masonry wall in
      dry weather.  you should:

ansrbtn.jpg (1340 bytes) (a)  wet the blocks while installing

ansrbtn.jpg (1340 bytes) (b)  never wet the blocks

ansrbtn.jpg (1340 bytes) (c)  wet the blocks after installing

ansrbtn.jpg (1340 bytes) (d)  wet the blocks before installing

76. Before any grout is poured in a hollow unit masonry wall,
       an inspector checks to make sure that:

ansrbtn.jpg (1340 bytes) (a)  rebar is in place

ansrbtn.jpg (1340 bytes) (b)  no obstructions are in the cells

ansrbtn.jpg (1340 bytes) (c)  it is level and plumb

ansrbtn.jpg (1340 bytes) (d)  all of the above

77. What type mortar option is best for interior non
      load bearing walls?

ansrbtn.jpg (1340 bytes) (a)  K = low compressive and bond strength or N = medium strength, high exposure

ansrbtn.jpg (1340 bytes) (b)  M = high compressive and bond strength or S = medium high compressive and bond strength

ansrbtn.jpg (1340 bytes) (c)  N = med. strength, high exposure or O = medium low compressive strength limited exposure

ansrbtn.jpg (1340 bytes) (d)  S = med. high compressive and bond strength or N = medium strength, high exposure

78. What is terrazzo and what is it used for?

ansrbtn.jpg (1340 bytes) (a)  an Italian style terrace for exterior exposure

ansrbtn.jpg (1340 bytes) (b)  a brand of stucco for exterior walls

ansrbtn.jpg (1340 bytes) (c)  marble chips are embedded in mortar, used for flooring

ansrbtn.jpg (1340 bytes) (d)  a brand for a form of BX cable used for refrigeration

79. When should clay brick require wetting?

ansrbtn.jpg (1340 bytes) (a)  when water absorbs within one minute of applying test droplets

ansrbtn.jpg (1340 bytes) (b)  if it flakes due to lack of moisture

ansrbtn.jpg (1340 bytes) (c)  clay brick does not require wetting

ansrbtn.jpg (1340 bytes) (d)  only concrete brick requires wetting

80. "Alligator" or crawl are terms when paint reacts from:

ansrbtn.jpg (1340 bytes) (a)   applying a hard finish coat over a soft priming surface

ansrbtn.jpg (1340 bytes) (b)  applying a soft finish coat over a hard priming coat

ansrbtn.jpg (1340 bytes) (c)  applying paint to a raw surface

ansrbtn.jpg (1340 bytes) (d)  moisture in the air

81. The next step after sandblasting a metal building?

ansrbtn.jpg (1340 bytes) (a)  wash with an alkaline cleaner

ansrbtn.jpg (1340 bytes) (b)  paint a sealer

ansrbtn.jpg (1340 bytes) (c)  paint the same day

ansrbtn.jpg (1340 bytes) (d)  all of the above

82. When painting with latex, paint brushes should
       be cleaned with:

ansrbtn.jpg (1340 bytes) (a)  turpentine

ansrbtn.jpg (1340 bytes) (b)  soap and water

ansrbtn.jpg (1340 bytes) (c)  solvent

ansrbtn.jpg (1340 bytes) (d)  thinner

83. When installing wallpaper your best surface is:

ansrbtn.jpg (1340 bytes) (a)  a sanded finish

ansrbtn.jpg (1340 bytes) (b)  plywood

ansrbtn.jpg (1340 bytes) (c)  metal

ansrbtn.jpg (1340 bytes) (d)  plaster

84. Which protective coating is the most scratch
      and chip resistant?

ansrbtn.jpg (1340 bytes) (a)  lacquer

ansrbtn.jpg (1340 bytes) (b)   polyurethane

ansrbtn.jpg (1340 bytes) (c)  latex paint

ansrbtn.jpg (1340 bytes) (d)  oil-based paint

85. What is a notable drawback of a natural bristle brush?

ansrbtn.jpg (1340 bytes) (a)  it leaves brush strokes

ansrbtn.jpg (1340 bytes) (b)  it has flag ends

ansrbtn.jpg (1340 bytes) (c)  it does not last as long as synthetic bristle brushes

ansrbtn.jpg (1340 bytes) (d)  it's hard to clean

86. Excavation for drainage pipe may be done at what
      distance from any footing?

ansrbtn.jpg (1340 bytes) (a)  8 feet

ansrbtn.jpg (1340 bytes) (b)  3 feet

ansrbtn.jpg (1340 bytes) (c)  no less than the depth of the excavation

ansrbtn.jpg (1340 bytes) (d)  as far from the edge as the height of the wall

87. Is it possible for PVC piping to go through or be
      embedded in concrete?

ansrbtn.jpg (1340 bytes) (a)  no, rigid copper pipe only

ansrbtn.jpg (1340 bytes) (b)  no, galvanized pipe only

ansrbtn.jpg (1340 bytes) (c)  yes

ansrbtn.jpg (1340 bytes) (d)  yes, but only outside the building

88. For stucco, the required setting time between the
      (scratch) or setting coat and the brown coat is:

ansrbtn.jpg (1340 bytes) (A)   no more than 9 days

ansrbtn.jpg (1340 bytes) (B)   7 days

ansrbtn.jpg (1340 bytes) (C)   4 days

ansrbtn.jpg (1340 bytes) (D)   2 days

89. What type of plaster should you use when working
      with a surface such as concrete:

ansrbtn.jpg (1340 bytes) (a)  neat

ansrbtn.jpg (1340 bytes) (b)  bond

ansrbtn.jpg (1340 bytes) (c)  wood fiber

ansrbtn.jpg (1340 bytes) (d)  gauging

90. The length used for sizing water piping, is measured
       from the located water meter to:

ansrbtn.jpg (1340 bytes) (a)  a remote outlet

ansrbtn.jpg (1340 bytes) (b)  the first branch

ansrbtn.jpg (1340 bytes) (c)  the water heater location

ansrbtn.jpg (1340 bytes) (d)  the first flushometer branch

91. Cleanouts under floors shouldn't be more
      than ___ feet from a crawl hole or access door

ansrbtn.jpg (1340 bytes) (a)  5 ft

ansrbtn.jpg (1340 bytes) (b)  10 ft

ansrbtn.jpg (1340 bytes) (c)  15 ft

ansrbtn.jpg (1340 bytes) (d)  20 ft

 

  Call us Today at 800-456-2150                      Questions@IndustrySchools.com  
  Home Page     Copyright © 1984-2008 Industry Schools,  02/05/08    Order Now